| Type: | Klinger MLG |
| Material: | AISI 316L / 1.4401 / 1.4404 |
| Alternative materials such as Titanium, Hastelloy, 1.4571 | |
| Connection: | Various connection options depending on design |
| Float: |
Sealed, freely moving and pressureless
|
| 360° magnetic field | |
| Coating: ECTFE (max. 150 °C) PFA (max. 270 °C) |
|
| Display : | Aluminium |
| Stainless steel (AISI 316) | |
| Polycarbonate | |
|
Red/white indicator flags – rotatable and vibration‑resistant
|
|
|
Operating Pressure:
|
Up to 200 bar |
| Temperature: | -100 °C … +400 °C |
| Steam boilers up til 120 bar | |
|
Approvals:
|
EN 13445 |
| ASME VIII div. 1 | |
| Lloyd’s | |
| ATEX | |
| Bureau Veritas | |
| Options: | Magnetic switches |
|
Level transmitters
|
|
|
Insulation
|
|
|
Steam and electric tracing
|
|
|
Special materials (fx 254SMO, Monel, PP, PVDF, UPVC)
|
|
|
Internal PTFE coating (AISI 316L)
|
|
|
Ordering Information
|
|
| Please Specify: |
Pressure and temperature (operating and design)
|
|
Process connection and centre‑to‑centre distance
|
|
|
Medium and specific gravity (SG)
|
|
| Any requirements for materials and approvals |
High Operational Reliability
Sealed and pressureless float system without through‑connections minimises the risk of leakage.
A measuring chamber designed as a parallel tube is placed on the outside of the tank with the level to be measured. A magnetic float is placed in the measuring chamber. This will follow the liquid’s surface so that the tank contents become visualized, by allowing the magnet to affect the roller scale mounted outside of the measuring chamber. The float’s position thus appears on the outside of the pipe, on a scale roller, typically via a color change. Bypass systems are available in lengths from 150mm up to 25.000mm, and can be equipped with external switches and transmitters.