PRODUCTS
  • KLINGER Ventiler DVK  structure layout 1
  • KLINGER Ventiler DVK measurement structure layout 2
  • KLINGER Ventiler DVK  structure layout 0
  • KLINGER Ventiler DVK measurement structure layout 1

Klinger water level fittings

flange

Application: Blades transparent viewers type T85, TA120, KTA or KT75.

DVK2 luminaire is proven and extremely robust.

Ball protection is standard.

 

General data

Type: DVK2 

Material: Steel C22.8 (FS / H).

Pressure range: PN315 / PN250 / pn160 

Upper: Steel C22.8 

Knob: GG20 

Valve cone Stainless steel 4528 V 

Spindle: Stainless steel 1.4104 

Seat: Stainless steel 1.4571 

Stem nut: Sint C11 

Stem Graphite 

Fuse Ball: Stainless steel 1.4034 

 

Connections: Flanges DN25. Other connections on request. 

 

When ordering, specify: 

- type 

- shows the type 

- pressure, temperature and media 

- connection

 

Type: DVK2

GENERALLY DIMENSIONER (mm)
Item no. Type service A / B C / H fl. ØD/pcd/bolth.
- DVK2 DN25 PN315 handwheel 320 / 256 389 / 245 160 / 115 / 4 stk
- DVK2 DN25 PN250 handwheel 320 / 256 389 / 245 150 / 105 / 4 stk
- DVK2 DN25PN160 handwheel 320 / 256 389 / 245 140 / 100 / 4 stk

Valves for level gauges

When a Bypass gauge is mounted, it is a good idea to use isolating valves in order to isolate the tank from the measuring system - e.g. for maintenance. Klinger offers versatile mounting accessories, such as drainage and isolation valves - components that complement your measurement.

 

This webpage uses cookies to ensure you the best experience on the page. Learn more