Klinger Field 401 is a Robust Transmitter, delivered with display, for most applications in all kind of Industry.
Generel data
Type: | Klinger Field 401 |
Process Connection: | G½” B or M20x1,5 |
Material Housing: | Aluminium / painted |
Wetted Parts: | Stainless Steel 1.4301 (304) or 1.4404 (316L) |
Ranges: | Sensor 1 (low pressure) 10 mbar … 40 mbar |
Sensor 2 (standard) 40 mbar … 100 bar | |
Sensor 3 (high pressure) 100 bar … 1.000 bar | |
Actual range can be adjusted within these limits | |
Calibration Certificate follows every transmitter | |
Max pressure: | 150% FS |
Accuracy: | 0.2 % FS |
Option: ≤ 0.1 % or 0,5% | |
Output: | 4...20 mA w. HART protokol |
RS485 (Modbus) |
|
Electrical Connection: | Separate Terminal box |
Display: | LCD intelligent |
Klinger 401A are SIL 2 certificeret |
Can be delivered in HT version (model Field 421) for process temperature max. 350oC
Varenummer | Type | Måleområde | Nøjagtighed | Tilslutning | Udgangssignal |
---|---|---|---|---|---|
19103264 | 401A-1Bar-2-G-6-4-S-2-M5 | 0 ... 1 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103265 | 401A-2,5Bar-2-G-6-4-S-2-M5 | 0 ... 2,5 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103266 | 401A-4Bar-2-G-6-4-S-2-M5 | 0 ... 4 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103267 | 401A-6Bar-2-G-6-4-S-2-M5 | 0 ... 6 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103268 | 401A-10Bar-2-G-6-4-S-2-M5 | 0 ... 10 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103269 | 401A-16Bar-2-G-6-4-S-2-M5 | 0 ... 16 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103270 | 401A-25Bar-2-G-6-4-S-2-M5 | 0 ... 25 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103271 | 401A-40Bar-2-G-6-4-S-2-M5 | 0 ... 40 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103272 | 401A-60Bar-2-G-6-4-S-2-M5 | 0 ... 60 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103273 | 401A-100Bar-2-G-6-4-S-2-M5 | 0 ... 100 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103274 | 401A-160Bar-2-G-6-4-S-2-M5 | 0 ... 160 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
19103275 | 401A-250Bar-2-G-6-4-S-2-M5 | 0 ... 250 bar | +/- 0,2% FS | G 1/2B | 4...20mA / HART m. LCD display |
We deliver Pressure Transmitters for measuring and monitoring pressure for most measuring tasks within the industry. The transmitters are standard with analog output signal, but we also offer SMART transmitters with both HART protocol and the option of connection to a fieldbus.
The measuring ranges go from 0… 25mbar up to 0… 1,000 bar, in accuracy classes down to 0.1%.