Ultrasonic Level Transmitter

 

Klinger ULM Ultrasonic level transmitter are a non-contact measurement device that can be used to measure fluid levels in tanks and bassins. The transmitter uses a piezo element that emits high-frequency sound waves in the range around 40kHz for the measurement.

We deliver in both compact and separate versions - both are equipped with display and menu operation as standard

  • Ranges max 30m
  • Delivered with integrated display for status and programmering
  • Adjusteable range and alarm levels

General data

Type:  Klinger ULM
Process Connection: Thread M78 x 2
Probe: PTFE or PVDF
Range: 0...5 m to 0...30 m (4 sensor types)
Accuracy: 3 mm or 0,1 % (Highest value are valid)
Response time: < 1 sec
Temperature range: -20°C ... 55°C
Output: 4…20mA and/or 2 switch (Relay)
Power Supply: 220VAC or 24VDC

 

Also available for Open Channel flow measurement - ask for more information

Type: Klinger ULM

  • Datablad (DK)
  • Datablad (UK)
  • Manual (UK)
  • Kontakt osContact us
Varenummer Produktkode Måleområde Udførelse Udgangs signal Forsyning Lagervare
19103068 ULM-05-DC-S-1-1-PT 5 meter Kompakt med display 4...20mA / 2-wire 24VDC
19103069 ULM-10-DC-S-1-1-PT 10 meter Kompakt med display 4...20mA / 2-wire 24VDC
19103070 ULM-15-DC-S-1-1-PT 15 meter Kompakt med display 4...20mA / 2-wire 24VDC
19103071 ULM-05-DC-S-1-3-PT 5 meter Kompakt med display 4...20mA / 2 stk relæ 24VDC
19103072 ULM-10-DC-S-1-3-PT 10 meter Kompakt med display 4...20mA / 2 stk relæ 24VDC
19103073 ULM-15-DC-S-1-3-PT 15 meter Kompakt med display 4...20mA / 2 stk relæ 24VDC
19103074 ULM-05-AC-L-1-3-PT 5 meter Adskilt inkl. 10m kabel 4...20mA / 2 stk relæ 220 VAC 50Hz
19103075 ULM-10-AC-L-1-3-PT 10 meter Adskilt inkl. 10m kabel 4...20mA / 2 stk relæ 220 VAC 50Hz
19103076 ULM-15-AC-L-1-3-PT 15 meter Adskilt inkl. 10m kabel 4...20mA / 2 stk relæ 220 VAC 50Hz

Time of Flight

Level measurement with Time and Flight principles is reflection or echo measurement based on measuring the duration of a high-frequency pulse emitted by a sensor - The pulse is reflected by the surface and detected again by the sensor.
The elapsed time is a measure of the distance traveled in the empty part of the tank. By now subtracting this value from the total tank height, the level height is obtained which, via an amplifier, is converted into a contact signal or an analog output signal.

 